AQUAVERN - Cable Specifications

Application

AQUAVERN cable is used as a cost effective alternative to rubber insulated cables for boreholes, drainage, dewatering, cleaning and irrigation pumping equipment. It is used on farms and in mines, dockyards, municipalities, construction operations, railways, roadworks and factories.

PVC is superior to rubber in a waterproof submersible cable. AQUAVERN cable therefore can be used for supplying power to all types of indoor and outdoor, mobile, portable and fixed pumping equipment.

Construction

High conductivity bunched flexible copper conductors, insulated and colour coded with general purpose waterproof flexible PVC. Insulated cores are twisted together and filled with PVC to give the cable a round finish. Final protection is with a tightly bonded waterproof, flexible PVC sheath.

aquavern-submersible-PVC-flexible-pump-cable
SPECIFICATION
Voltage Rating
Test Voltage
Current Capacity AC
Temperature range
Flexibility Class
Conductor Type
Insulation Material
Sheath Material
Sheath Colours
Core Colours
 
(SABS 1574)
600/1000 Volts
3000 Volts
As per table below
-10˚ to +80˚C
4 & 5
High conductivity annealed copper
Flexible grade waterproof PVC
Flexible grade waterproof PVC
3 core – Blue, 4 core – Green
3 core – Red, Yellow, Blue
4 core – Red, Yellow, Blue, Black

TECHNICAL DATA

Size mm²Stranding No x Dia600/1000VmV dropNominal DiaMass Kg/100m
Cubicle Wiring Amp RatingsAmp / mtr
1ph 220V3ph 380V1ph 220V3ph 380V
1.5     3c28 x 0.261615292510.114.96
2.5     3c44 x 0.262320181511.119.30
4.0     3c49 x 0.313027119.513.027.65
6.0     3c74 x 0.3138347.36.414.737.82
10.0   3c126 x 0.3152464.43.816.955.77
16.0   3c200 x 0.3169622.82.418.976.38
1.5     4c28 x 0.261615292510.917.70
2.5     4c44 x 0.262320181512.023.12
4.0     4c49 x 0.313027119.514.234.10
6.0     4c72 x 0.3138347.36.416.046.00
10.0   4c126 x 0.3152464.43.818.568.67
16.0   4c200 x 0.3169622.82.420.794.87

Packaging

Available in 500 metre drum lengths. Cut lengths are also available on request.

This product is sequentially marked at one metre intervals for your convenience and security.